NewAnalogue signal conditioning
AD-LW 110 GVC
Load monitor for cos phi and undervoltage with adjustable limits

Manufacturer image of the device family. The actual version may differ.
Analogue multifunction signal isolator with signal-combination selection via terminals
Price and delivery time on request. Personal advice from Grubatec.
The AD-TV 300 GS isolates, amplifies and converts standard analogue signals using an input/output combination selected through the connection terminals. One input and one output are used to adapt a measurement signal; no subsequent adjustment is required.
| Manufacturer | Adamczewski Elektronische Messtechnik GmbH |
|---|---|
| Model | AD-TV 300 GS |
| Function | Analogue multifunction signal isolator with signal-combination selection via terminals |
| Input | Standard analogue signal input |
| Output | Standard analogue signal output |
| Power supply | Wide-range power supply |
| Housing type | GS |
| Input types | Unipolar standard signal |
| Output types | Unipolar standard signal |
| Supply types | Wide range, DC 20-30V, AC 230V |
| Design | DIN rail, screw terminals |
| Device functions | Standard signal conversion, galvanic isolation (I/O), 1:1 standard signal isolation |
| Measuring range 1 | 0 ... 20 mA |
|---|---|
| Measuring range 2 | 4 ... 20 mA |
| Input resistance 1/2 | 50 Ohm |
| Measuring range | 0 ... 10 V |
|---|---|
| Input resistance | 750 kOhm |
| Output range 1 | 0 ... 20 mA |
|---|---|
| Output range 2 | 4 ... 20 mA |
| Maximum load 1/2 | 500 Ohm |
| Simultaneous use | No |
| Output range | 0 ... 10 V |
|---|---|
| Minimum load | 1000 Ohm |
| Voltage range | 50 ... 253 V AC (50 Hz),20 ... 253 V DC |
|---|---|
| Rated voltage | 230 V AC (50 Hz), 24 V DC |
| Power consumption | 4 VA, 2 W |
| Basic accuracy | < 0,2 % |
|---|---|
| Temperature influence | 100 ppm/K |
| Response time | ~ 50 ms (10...90 % output signal) |
| Dimensions (w×h×d) | 18x78x103 mm |
|---|---|
| IP rating | IP 20 |
| Connection technology | Screw terminals |
| Terminal conductor cross-section | 2.5 mm² stranded wire / 4 mm² solid wire |
| Terminal tightening torque | 0.5 Nm |
| Weight | ~ 140 g |
| Construction | 35 mm DIN rail |
| Ambient temperature | -10 ... 50 °C |
|---|---|
| Storage and transport | -10 ... 70 °C (avoid condensation) |
| Product family standard | EN 61326-1 1) |
|---|---|
| Emissions | EN 55011, CISPR11 class B, group 1 |
| Product family standard | EN 61010-1 |
|---|---|
| Overvoltage category | II |
| Pollution degree | 2 |
| Input to output | 3.75 kV, 50 Hz (1 min.) |
|---|---|
| Input, output to power supply | 3 kV, 50 Hz (1 min.) |
| Note | 1) Minor signal deviations may occur during interference. |
|---|
Unsure about the input signal, output or version? Describe your application to us. Together, we will find the appropriate Adamczewski device.