Back to analogue signal processing
Product image of the device family – Grubatec – AD-SWK 3 WG – AC signal isolator

Manufacturer image of the device family. The actual version may differ.

Analogue signal conditioning

AD-SWK 3 WG

Three-channel AC signal isolator with split-core current transformers and sinusoidal voltage output

Housing type WGDIN rail
Input
AC currents
Output
Sinusoidal voltage
Power supply
Wide-range power supply
Housing type
WG
Datasheet (EN)

Price and delivery time on request. Personal advice from Grubatec.

Model overview.

The AD-SWK 3 WG converts up to three independent alternating currents into sinusoidal voltage signals using split-core current transformers. The frequency characteristics of each input signal are preserved for further processing; inputs, outputs and supply are galvanically isolated, with the outputs sharing a common ground.

ManufacturerAdamczewski Elektronische Messtechnik GmbH
ModelAD-SWK 3 WG
FunctionThree-channel AC signal isolator with split-core current transformers and sinusoidal voltage output
InputAC currents
OutputSinusoidal voltage
Power supplyWide-range power supply
Housing typeWG
Input typesAC quantities
Output typesAC signals
Supply typesWide range, DC 20-30V, AC 230V
DesignDIN rail
Device functionsgalvanic isolation (I/O)
Further technical data for the device family
These details come from the manufacturer’s shared page for the device family. Where several versions exist, individual values apply only to the variant specified. The data sheet for your particular version is authoritative.

Inputs

Measuring range0 ... 3 A AC peak (0 ... 2.12 A AC RMS)
Maximum measuring range0 ... 10 A AC peak (0 ... 7.07 A AC RMS)
Max. measurable harmonic80 (4 kHz)
Conductor diameter (internal)<8 mm
Continuous overload120 % of the rated value
Short-term overload (1s)Twenty times the rated value

Outputs

Output range0 ... 10 V AC peak (0 ... 7.07 V AC RMS)
Minimum load10 kOhm

Overall accuracy

Device<0,5 %
Temperature influence<100 ppm / K
Input/output phase shiftOutput 3.6° lagging

Power supply

AC supply voltage50 ... 253 V AC
Rated AC voltage230 V AC
DC supply voltage20 ... 253 V DC
Rated DC voltage24 V DC
AC/DC power consumption1.8 VA / 0.8 W

Housing

Connection technologySpring-clamp terminals
Input connection technologySplit-core current transformer
Construction35 mm DIN rail
Dimensions (w×h×d)138x80x64(88)mm
Weight~ 280 g

Ambient conditions

Ambient temperature-10 ... 50 °C
Storage and transport-10 ... 70 °C (avoid condensation)

EMC

Product family standardEN 61326-1
EmissionsEN 55011, CISPR11 class B, group 1
NoteMinor signal deviations may occur during interference.

Electrical safety

Product family standardEN 61010-1
Overvoltage categoryII
Pollution degree2

Galvanic isolation, test voltages

Input/output2.2 kV AC + test voltage of the cable
Signal/power supply3 kV RMS

Protective circuit

Input/outputOvervoltage, overcurrent
Power supply unitOvercurrent, overvoltage, overtemperature
Personal. Technical. Solution-focused.

Your measurement task deserves
the right solution.

Unsure about the input signal, output or version? Describe your application to us. Together, we will find the appropriate Adamczewski device.

+41 55 617 00 80
GRUBATEC Mess- und Regeltechnik