Analogue signal conditioning
AD-SWT 50 SO
50 A AC current-transformer transmitter with split-core design and 4...20 mA output

Manufacturer image of the device family. The actual version may differ.
100 A AC current-transformer transmitter with split-core design and 4...20 mA output
Price and delivery time on request. Personal advice from Grubatec.
The AD-SWT 100 SO measures sinusoidal alternating currents up to 100 A and converts them into a proportional 4...20 mA transmitter signal. The two-wire design is powered through the output; the split-core housing simplifies retrofitting, for example to measure motor or pump currents.
| Manufacturer | Adamczewski Elektronische Messtechnik GmbH |
|---|---|
| Model | AD-SWT 100 SO |
| Function | 100 A AC current-transformer transmitter with split-core design and 4...20 mA output |
| Input | AC currents |
| Output | Standard analogue signal output (current sink) |
| Power supply | Power supplied through the output (transmitter supply voltage) |
| Housing type | Not specified |
| Input types | AC quantities |
| Output types | Unipolar standard signal |
| Supply types | Transmitter |
| Design | Screw terminals |
| Device functions | galvanic isolation (I/O) |
| Measurement method | Inductive |
|---|---|
| Measuring range | 0 ... 50/100/200 A AC |
| Max. conductor diameter | 23 mm |
| Output range | 4 ... 20 mA |
|---|---|
| Ripple | 50 µA p-p |
| DC voltage range | 10 ... 30 V DC |
|---|---|
| Rated DC voltage | 24 V DC |
| Basic accuracy | < 1 % |
|---|---|
| Temperature influence | 100 ppm/K |
| Response time | < 2 s (10...90 %) |
| Dimensions (w×h×d) | 50x42x82 mm |
|---|---|
| IP rating | IP 20 |
| Connection technology | Screw terminals |
| Terminal conductor cross-section | 1.5 mm² stranded wire / 2.5 mm² solid wire |
| Terminal tightening torque | 0.5 Nm |
| Weight | ~ 200 g |
| Construction | Split-core transformer housing |
| Ambient temperature | -10 ... 50 °C |
|---|---|
| Storage and transport | -10 ... 70 °C (avoid condensation) |
| Product family standard | EN 61326-1 1) |
|---|---|
| Emissions | EN 55011, CISPR11 class B, group 1 |
| Product family standard | EN 61010-1 |
|---|---|
| Overvoltage category | II |
| Pollution degree | 2 |
| Measurement circuit safety | 61010-2-030 |
| Measurement category | CAT III |
| Input / output | 4 kV, 50 Hz (1 min.) |
|---|
| Output | Protection against overvoltage and reverse polarity |
|---|
| Note | 1) Minor signal deviations may occur during interference. |
|---|
Models in the same device family. Differences may include inputs and outputs, power supply or housing type.
Unsure about the input signal, output or version? Describe your application to us. Together, we will find the appropriate Adamczewski device.