Price and delivery time on request. Personal advice from Grubatec.
Model overview.
The AD-KR 11 GX isolates and amplifies contact signals using one changeover contact and a 24 V DC auxiliary supply. This slim interface relay indicates its switching state with a red LED and incorporates a flyback diode and reverse-polarity protection.
Manufacturer
Adamczewski Elektronische Messtechnik GmbH
Model
AD-KR 11 GX
Function
Single-channel interface relay with one changeover contact for galvanic contact isolation
Input
Pulse input
Output
Relay
Power supply
24V DC
Housing type
GX
Input types
Pulses, logic inputs
Output types
Relay, S0, pulses
Supply types
none
Design
DIN rail, screw terminals, 6.3 mm width
Device functions
galvanic isolation (I/O), quantity pulses, energy pulses
Further technical data for the device family
These details come from the manufacturer’s shared page for the device family. Where several versions exist, individual values apply only to the variant specified. The data sheet for your particular version is authoritative.
Input
Rated voltage
24 V DC
Voltage range
20 ... 30 V DC
Response time
6 ms
Release time
6 ms
Relay output
Maximum AC switching load
250 V, 2 A
Maximum DC switching load
50 V, 2 A
AC switching capacity
< 100 VA
DC switching capacity
< 100 W
Switching frequency
< 1 Hz
Mechanical switching cycles
10000000
At 230V/2A AC, cos(phi)=1
600000
At 230V/2A AC, cos(phi)=0.4
200000
At 24V/1 A DC
200000
Contact configuration
AD-KR 11 GX
1 volt-free changeover contact
AD-KR 12 GX
2 volt-free normally open contacts
AD-KR 22 GX
2 volt-free normally open contacts
Housing
Dimensions (W×H×D)
6.2 x 92 x 101 mm³
IP rating
IP 20
Connection technology
Screw terminals
Terminal conductor cross-section
2.5 mm² stranded wire / 4 mm² solid wire
Terminal tightening torque
0.5 Nm
Weight
~ 100 g
Construction
DIN rail 35mm, EN 50022
Ambient conditions
Ambient temperature
-10 ... 50 °C
Storage and transport
-10 ... +70 °C (avoid condensation)
EMC
Product family standard
EN 61326-1
Emissions
EN 55011, CISPR11 class B, group 1
Electrical safety
Product family standard
EN 61010-1
Overvoltage category
II
Pollution degree
2
Galvanic isolation, test voltages
Input to contact
1.5 kV, 50 Hz (1 min)
Contact to contact
1.5 kV, 50 Hz (1 min)
Protective circuits
Inputs
Protection against overvoltage