The AD-VC 5 GVF-R0 processes signals from resistance thermometers, thermocouples or mV sources and shows the measured value on an LCD. Current and voltage outputs can be scaled differently and used simultaneously; adaptation to the sensor is carried out directly on the device or using AD-Studio.
| Manufacturer | Adamczewski Elektronische Messtechnik GmbH |
|---|---|
| Model | AD-VC 5 GVF-R0 |
| Function | Digital temperature transmitter with LCD and two standard analogue signal outputs |
| Input | RTD, PT, NI, thermocouples, mV |
| Output | Standard analogue signal output |
| Power supply | Wide-range power supply |
| Housing type | GVF |
| Input types | Temperature, mV-DC |
| Output types | Unipolar standard signal |
| Supply types | Wide range, DC 20-30V, AC 230V |
| Interface / protocols | AD-UART |
| Display / operation | LCD |
| Design | DIN rail, plug-in terminals, screw terminals |
| Device functions | Simulation, freely configurable, standard signal conversion, galvanic isolation (I/O), 1:1 standard signal isolation, setpoint generation, freely scalable |
| Measuring range | -200 ... +850 °C |
|---|---|
| Connection technology | 2-wire, 3-wire or 4-wire |
| Resolution | 16 bit |
| Accuracy | 0.5 K |
| Minimum measurement span | 20 K |
| Max. lead resistance 1) | 10 Ohm/conductor |
| Note | Sensor power supply |
| Pt100 | 1 mA |
| Pt500, Pt1000 | 210 µA |
| Note | 1) With a 2-wire connection, lead resistance introduces an offset into the measurement. |
| Measuring range | -60 ... +230 °C |
|---|---|
| Connection technology | 2-wire, 3-wire or 4-wire |
| Resolution | 16 bit |
| Accuracy | 0.5 K |
| Minimum measurement span | 20 K |
| Max. lead resistance 1) | 10 Ohm/conductor |
| Note | Sensor power supply |
| Ni100 | 1 mA |
| Ni500, Ni1000 | 210 µA |
| Note | 1) With a 2-wire connection, lead resistance introduces an offset into the measurement. |
| Note | Cold junction: |
|---|---|
| Internal | Measurement with LM35 at the device terminals |
| External | Cold-junction temperature selectable via parameter |
| Resolution | 16 bit |
| Accuracy | 0.2 % of the measuring range |
| Measuring range type J | -200 ... +1200 °C |
| Note | According to DIN EN 60584: |
| Measuring range type T | -200 ... +400 °C |
| Measuring range type K | -200 ... +1360 °C |
| Measuring range type E | -200 ... +1000 °C |
| Measuring range type N | -200 ... +1300 °C |
| Measuring range type S | -40 ... +1760 °C |
| Measuring range type R | -40 ... +1760 °C |
| Measuring range type B | +400 ... +1800 °C |
| Note | According to ASTM standard E988: |
| Measuring range type C | 0 ... +2320 °C |
| Minimum measurement span | 100 K |
| Measuring ranges | -18 ... +18 mV |
|---|---|
| -36 ... +36 mV | |
| -72 ... +72 mV | |
| -144 ... +144 mV |
| Output range | 0 ... 20.4 mA |
|---|---|
| Resolution | 10 bit |
| Accuracy | 20 µA |
| Maximum load | 500 Ohm |
| Ripple | 20 µA p-p |
| Output range | 0 ... 10.2 V |
|---|---|
| Resolution | 10 bit |
| Accuracy | 10 mV |
| Minimum load | 5 kOhm |
| Ripple | 10 mV p-p |
| Note | When current and voltage outputs are used simultaneously, the two circuits must not be connected together. |
| Max. switching voltage | AC 250 V AC |
|---|---|
| Max. AC switching current | 2 A AC |
| Max. switching voltage | DC 50 V DC |
| Max. DC switching current | 2 A DC |
| Graphic LCD | 42x64 pixels, RGB backlight |
|---|---|
| Digital display | 4-digit, configurable |
| Display function | Scaled input signal, input signal, outputs, limits, scaled value as a bar graph, scaling unit |
| Measurement rate | 1 measurement/s |
|---|---|
| Linearity error | 0.2 % of full scale |
| Temperature influence | +/-100 ppm/K of full scale |
| Supply voltage | 50 ... 253 V AC |
|---|---|
| 20 ... 253 V DC | |
| Max. power consumption at 24V DC | 2.6 W |
| Max. power consumption at 230V AC | 5 VA |
| Dimensions | W×H×D 33x110x128 mm |
|---|---|
| Construction | DIN rail 35mm, EN 50022 |
| IP rating | IP 20 |
| Connection technology | Removable screw terminals, 5 mm pitch |
| Conductor cross-section | Max. 2.5 mm2 |
| Weight | ~ 200 g |
| Permissible ambient temperature | -10 ... +60 °C |
|---|---|
| Storage and transport | -10 ... 70 °C (avoid condensation) |
| Product family standard 1) | EN 61326-1 |
|---|---|
| Emissions | EN 55011, CISR11 class B, group 1 |
| Note | 1) Minor signal deviations may occur during testing. |
| Product family standard | EN 61010-1 |
|---|
| Input to outputs | 2.5 kV, 1min |
|---|---|
| Input/outputs to auxiliary supply | 4 kV, 1min |
| Between outputs | No galvanic isolation |
| Input to programming interface | No galvanic isolation |