Type VMI TriClamp induQ® Magnetic-Inductive Flow Sensor
Precise Flow Measurement of Conductive Liquids with TriClamp Connection
VMI TriClamp induQ® Magnetic-Inductive Flow Sensor
The induQ® VMI Series magnetic-inductive flow sensors enable reliable and precise measurement of flow rate and volumetric flow in electrically conductive liquids.
The measurement is performed without any moving parts. As a result, the sensor operates with minimal wear and requires no maintenance, making it particularly well-suited for industrial applications that require consistently reliable flow measurement.
Sturdy metal construction with TriClamp connection
The TriClamp version combines a robust metal housing with process connections compliant with ISO 2852. The process connections and electrodes that come into contact with the medium are made of 1.4571 stainless steel.
The sensors are available in nominal diameters of DN 7, DN 10, and DN 20 and cover flow rates up to 250 l/min.
Magnetic-inductive measurement principle
The measurement principle is suitable for water and other electrically conductive liquids. The flow rate is determined based on the electrical voltage generated in a magnetic field. Since the measurement system contains no mechanically moving components, the VMI series offers high operational reliability and low maintenance requirements.
Flexible Output Signals
Depending on the model, either a frequency output or a combination of frequency and analog outputs is available. The analog signal options are 4…20 mA or 0…10 V. This allows the sensors to be flexibly connected to control systems, displays, and data acquisition units.
Typical Applications
VMI TriClamp flow sensors are suitable for a wide range of industrial plants, machines, and cooling and supply systems where conductive liquids need to be reliably monitored and measured.
Technical data
Technical data
| Measuring principle | Magnetic-inductive |
| Measuring medium | Water and other electrically conductive liquids |
| Min. Conductivity | 50 µS/cm |
| Nominal diameters | DN 7, DN 10, DN 20 |
| Process connection | TriClamp in accordance with ISO 2852 |
| Measuring range | up to 250 l/min, depending on the model |
| Response time | < 500 ms |
| Media temperature | -20…90 °C |
| Nominal pressure | PN 16 |
| Flow display | Green LED, flashing in proportion to the flow rate |
| Protection class | IP65 and IP67 with the connector plug attached |
| Electrical connection | M12 × 1 Circular Connector |
| Output Signals | Frequency; Frequency + 4–20 mA; Frequency + 0–10 V |
| Housing | Die-Cast Aluminum |
| Electrodes | Stainless steel 1.4571 |
| Process Connections | Stainless steel 1.4571 |
| Measuring tube | PEEK-GF30 |
| O-rings | EPDM, FKM (optional) |