PERITACT2000 - Differential pressure gauge 0...10000 Pa (100 mbar) Analog outputs 0...10 V, 0...20 mA or 4...20 mA, for air or non-aggressive gases
Measuring instrument with diaphragm measuring unit for displaying, monitoring and transmitting measured values of pressure, negative pressure or differential pressure of non-aggressive gases.
The Peritact can be ordered in the following variants:
Measuring range: 0...1000 Pa (10 mbar), 0...2000 Pa (20 mbar), 0...4000 Pa (40 mbar), 0...5000 Pa (50 mbar), 0...6000 Pa (60 mbar), 0...10000 Pa (100 mbar)
Output: 0...10V, 4...20 mA, 0...20 mA
Switching function: min or max
The measuring instrument with diaphragm measuring unit is suitable for displaying, monitoring and transmitting measured values of pressure, negative pressure or differential pressure of non-aggressive gases. It is capable of providing an accurate indication and can be adapted to specific requirements by means of optional extensions such as an adjustable pressure switch or up to two adjustable limit pointers. Accessories for mounting in front of or behind a control panel or for wall mounting are included.
| Operating mode: |
| Measuring mode |
| Measuring material: |
| Air or non-aggressive gases |
| Transducer: |
| Electromechanical diaphragm measuring unit |
| Measuring unit: |
| Pa |
| Smallest measuring span: |
| 0...50Pa (1mbar) |
| Largest measuring span: |
| 0...10000Pa (50mbar) |
| Measuring ranges: |
| 0...50 Pa (0.5 mbar), 0...100 Pa (1 mbar), 0...200 Pa (2 mbar), 0...400 Pa (4 mbar), 0...500 Pa (5 mbar), 0...1000 Pa (10 mbar), 0...2000 Pa (20 mbar), 0...4000 Pa (40 mbar), 0...5000 Pa (50 mbar), 0...6000 Pa (60 mbar), 0...10000 Pa (100 mbar) |
| Measuring range selection: |
| Preset ex works |
| Set point adjustment: |
| 2 setpoint pointers adjustable over the full scale range, 1 output relay per limit value with potential-free changeover contact |
| Contact load: |
| 250 Vac, 6A, non-inductive load |
| Ambient temperature: |
| -10...+50°C |
| Storage temperature: |
| -25...+60°C |
Technical data
- Diaphragm measuring unit
- Smallest measuring range 0...50 Pa
- Analog outputs 0...10 V, 0...20 mA or 4...20 mA
- Digital display 3 1/2 digits, digit height 13 mm
- Supply voltage 230 Vac, 24 Vac or 24 Vdc
- Wall mounted housing IP 65
- Two-wire version PERITACT 2000-2L