Test block Test equipment for checking the calibration accuracy for humimeter measuring devices with conductance measuring method
Test block for humimeter FL1, FL2, FLS, FLH, BLL, BL2, WLW, BLW, SLW, RM1 and BLO - Dimensions: 55 x 55 x 45 mm, weight: 96 g
Operating instructions for the test block for humimeter FL1, FL2, FLH, BLL, BL2, WLW, BLW, SLW, RM1 and BLO
The test block was developed to easily and precisely check the calibration of lances in various humimeter devices. With dimensions of 55 x 55 x 45 mm and a weight of 96 g, the test block is compact and easy to handle, ideal for a quick and efficient check of the entire measuring range.
Main features:
- Quick check: Enables a quick check of the entire measuring range.
- Precise instructions: The instructions provided ensure that the inspection process is easy to understand.
- Easy handling: The test block is user-friendly and can be used without special tools.
Description:
The test block offers an uncomplicated way to check the calibration of the lance of your humimeter measuring device. Using the special "test block" characteristic makes the checking process easier: all you have to do is place the measuring tip on the block. This test block allows you to test the calibration of the sensor at two specific points. If the measured value deviates from the target value, our competent support team or one of our sales partners will be happy to help you solve the problem.
Our test blocks are made of high-quality materials to ensure a long service life and high reliability. Regularly checking and calibrating your measuring devices with the test block ensures that they always work precisely and reliably. This is particularly important in areas where accurate measurementsare crucial, such as quality control, research and development and industrial production.
Cleaning:
- Electrodes: If the measuring head is dirty, it can be cleaned with alcohol.
- Test block: Dirt on the test block can be removed with a damp cloth.
Care instructions:
- Water protection: Do not leave the test block in the rain as it is not waterproof.
- Temperature conditions: Do not expose the test block to extreme temperatures.
- Mechanical loads: Avoid strong mechanical shocks or loads on the test block.
- Storage conditions: Store the test block in a room climate with a humidity of 30 to 70 % to ensure its longevity.
By using the test block regularly, you ensure that your humimeter measuring device remains accurately calibrated and continues to deliver precise measurement results in the long term.
Positioning the test block
The two electrodes of the test block must rest firmly on the metal parts in front of and behind the black plastic insulator.
The sensor tube or the measuring tip must be held in the air during the check
Humimeter BLL
" The two electrodes of the test block must rest firmly on the metal parts in front of and behind the transparent plastic insulator.
" The sensor tube or the measuring tip must be held in the air during the test.
humimeter WLW, BLW & SLW
" Remove the nails and nuts.
" The two electrodes of the test block must each be held in the holes of the grub screws.
" The electrodes must be held with light pressure on the grub screws.
" The measuring head must be held in the air during the test.
For more information, please click on the red boxes.