Type TP 17165S TP Solid dry block temperature calibrator -35...165 °C Accuracy ±0.2 °C

Compact design for on-site use / Easy calibration without regard to viscosities, flash points or outgassing / Large calibration volume for simultaneous calibration of many test specimens /Optimal thermal coupling from block to test specimen due to SIKA transition sleeves

Operating instructions for SIKA temperature calibrator type TP 17165S - TP Solid

The SIKA TP 17165S dry-block temperature calibrator (TP Solid) is a powerful, compact instrument designed specifically for on-site use. With a temperature range of -35 °C to 165 °C and an accuracy of ±0.2 °C, this calibrator offers a precise solution for calibrating temperature sensors in various industries:

  • Assembly and commissioning
  • Manufacturing and production
  • Maintenance and service
  • Quality assurance and test equipment monitoring
  • Repair

Features of the TP 17165S:

  • Temperature range: -35...165 °C
  • Accuracy: ±0.2 °C
  • Compact design: The TP Solid was developed for mobile use on site and offers great flexibility and easy handling.
  • Large calibration volume: The device enables the simultaneous calibration of several test specimens and thus ensures high efficiency.

Dry block and microbath function: Versatile calibration

The TP 17165S offers both a dry block and a microbath function, which enables versatile use in laboratories and in the field.

Microbath function:

  • The microbath function is particularly useful when calibrating temperature sensors with unusual shapes and dimensions.
  • Here, the test object is immersed directly in a calibration fluid, such as silicone oil, which ensures direct temperature transfer. As a result, there are no insulating air gaps and optimum temperature tightness between the calibrator and the test object is guaranteed.
  • The infinitely variable control of the magnetic agitator and the pull-out sensor basket ensure an even distribution of the calibration liquid and a uniform measuring zone. The basket protects the bottom of the tank and ensures an undisturbed stirring process.

Dry block function:

  • The dry block function enables simple and precise calibration of temperature sensors in laboratory and field applications.
  • By using the correct adapter sleeve, the optimum thermal coupling between the block and the test specimen is achieved. The sleeve should have an internal diameter that is approximately 0.5 mm larger than the external diameter of the test specimen.
  • Almost all straight temperature sensors with different lengths and diameters can be calibrated with the adapter sleeves.
  • The dry block covers the entire temperature range from -35 to 165 °C without having to change the calibration medium. The user therefore does not have to take viscosities, flash points or outgassing into account.

Technical data:

  • Temperature range: -35...165 °C
  • Accuracy: ±0.2 °C
  • Calibration media: Dry block and liquid (e.g. silicone oil)

Summary

The SIKA TP 17165S dry block temperature calibrator (TP Solid) offers a highly accurate, flexible and versatile solution for temperature calibration. Thanks to its micro-bath and dry-block function, it is ideal for calibrating both common and bulky temperature sensors. With a compact design, high accuracy and the ability to calibrate multiple test items simultaneously, the TP 17165S is the perfect choice for workshops, laboratories and test rooms that require efficiency, precision and ease of use.

Accuracy
±0,2 °C

Technical data

 

 