Type TP 17166S TP Solid dry block temperature calibrator -30...165 °CAccuracy ±0.2 °C
Compact design for on-site use / Easy calibration without regard to viscosities, flash points or outgassing / Large calibration volume for simultaneous calibration of many test specimens /Optimal thermal coupling from block to test specimen due to SIKA transition sleeves
Operating instructions for SIKA temperature calibrator type TP 17166S - TP Solid
The SIKA TP 17166S dry-block temperature calibrator (TP Solid) is a powerful, compact device that has been specially developed for on-site use. With a temperature range of -30 °C to 165 °C and an accuracy of ±0.2 °C, this calibrator is ideal for calibrating temperature sensors in various areas:
- Assembly and commissioning
- Manufacturing and production
- Maintenance and service
- Quality assurance and test equipment monitoring
- Repair
Features of the TP 17166S:
- Temperature range: -30...165 °C
- Accuracy: ±0.2 °C
- Compact design: Developed for mobile use on site, the TP Solid offers a high degree of flexibility and user-friendly operation.
- Large calibration volume: The device enables the simultaneous calibration of several test specimens, which leads to increased efficiency.
Microbath and dry block function: Flexible calibration
The TP 17166S offers both a microbath and a dry block function, designed for versatile applications in laboratories and in the field.
Microbath function:
- The microbath function is particularly useful for calibrating temperature sensors with unusual shapes and dimensions. The test item is immersed directly in a calibration liquid, such as silicone oil. This creates a direct temperature transfer without insulating air gaps and ensures optimum temperature tightness between the calibrator and the test item.
- The infinitely variable control of the magnetic agitator and the pull-out sensor basket ensure an even distribution of the calibration liquid and a uniform measuring zone. The basket protects the bottom of the tank and ensures an undisturbed stirring process.
Dry block function:
- The dry block function enables simple and precise calibration of temperature sensors both in the laboratory and on site.
- Optimum thermal coupling between the block and the test specimen is achievedby selecting the correct adapter sleeve. This should have an internal diameter that is 0.5 mm larger than the external diameter of the test specimen.
- The dry block covers the entire temperature range from -30 °C to 165 °C without having to change the calibration medium. The user does not have to worry about viscosities, flash points or outgassing, which makes the calibration process much easier and faster.
Technical data:
- Temperature range: -30...165 °C
- Accuracy: ±0.2 °C
- Calibration media: Dry block and liquid (e.g. silicone oil)
Summary
The SIKA TP 17166S dry block temperature calibrator (TP Solid) offers a precise, flexible and versatile solution for the calibration of temperature sensors. Thanks to the micro bath and dry block function, both bulky and straight temperature sensors can be calibrated efficiently. The compact design, high accuracy and ability to calibrate multiple test items simultaneously make the TP 17166S the ideal choice for workshops, test rooms and laboratories where efficiency, precision and ease of use are required.
| Accuracy |
| ±0,2 °C |
Technical data