Type TP 17200S TP Solid Dry Block Temperature Calibrator -55...200 °C Accuracy ±0.2 °C

Compact design for on-site use / Easy calibration without regard to viscosities, flash points or outgassing / Large calibration volume for simultaneous calibration of many test specimens /Optimal thermal coupling from block to test specimen due to SIKA transition sleeves

Operating instructions for SIKA temperature calibrator type TP 17200S - TP Solid

The SIKA TP 17200S dry-block temperature calibrator (TP Solid) is a compact, high-precision instrument designed specifically for on-site use. With a temperature range of -55 °C to 200 °C and an accuracy of ±0.2 °C, this calibrator offers a reliable solution for the calibration of temperature sensors in a wide range of applications:

  • Assembly and commissioning
  • Manufacturing and production
  • Maintenance and service
  • Quality assurance and test equipment monitoring
  • Repair

Features of the TP 17200S:

  • Temperature range: -55...200 °C
  • Accuracy: ±0.2 °C
  • Compact design: Developed for flexible use on site, the TP Solid ensures user-friendly handling and efficiency during calibrations.
  • Large calibration volume: Offers the possibility to calibrate several test samples simultaneously, which speeds up and optimizes the calibration process.

Dry block function: Precise and uncomplicated calibration

The dry block function of the TP 17200S has been specially developed to enable fast and precise calibrationboth in the laboratory and in the field. The use of the correct adapter sleeve ensures an optimum thermal connection between the block and the test specimen.

  • Optimum heat transfer: To ensure accurate calibration, the adapter sleeve should have an internal diameter that is approximately 0.5 mm larger than the external diameter of the test specimen. This measure ensures efficient thermal coupling.
  • Versatile application: The calibrator is able to calibrate almost all straight temperature sensors of differentlengths and diameters by using the appropriate adapter sleeves.

No need to change the calibration medium

The dry block covers the entire temperature range from -55 °C to 200 °C without the need to change the calibration medium. This means that the user does not have to take viscosities, flash points or outgassing into account, which makes the calibration process considerably easier and faster.

Technical data:

  • Temperature range: -55...200 °C
  • Accuracy: ±0.2 °C
  • Calibration medium: Dry block

Summary

The SIKA TP 17200S dry block temperature calibrator (TP Solid) offers a precise, efficient and user-friendly solution for the calibration of temperature sensors. The dry block function eliminates the need for liquid calibration media, making calibration safer, easier and faster. With its compact design, high accuracy and ability to calibrate multiple test samples simultaneously, the TP 17200S is the ideal choice for use in workshops, laboratories and test rooms that require reliability, efficiency and precision.

Accuracy
±0,2 °C