Type TP 17200S TP Solid Dry Block Temperature Calibrator -55...200 °C Accuracy ±0.2 °C

Compact design for on-site use / Easy calibration without regard to viscosities, flash points or outgassing / Large calibration volume for simultaneous calibration of many test specimens /Optimal thermal coupling from block to test specimen due to SIKA transition sleeves

Operating instructions for SIKA temperature calibrator type TP 17200S - TP Solid

The SIKA TP 17200S dry-block temperature calibrator (TP Solid) is a compact and high-precision device that has been specially developed for on-site use. With a temperature range of -55 °C to 200 °C and an accuracy of ±0.2 °C, the calibrator offers a reliable solution for the calibration of temperature sensors in various application areas:

  • Assembly and commissioning
  • Manufacturing and production
  • Maintenance and service
  • Quality assurance
  • Test equipment monitoring
  • Repair

Features of the TP 17200S:

  • Temperature range: -55...200 °C
  • Accuracy: ±0.2 °C
  • Compact design: The TP Solid is designed for mobile use on site, which enables high flexibility and simple operation.
  • Large calibration volume: The device enables the simultaneous calibration of several test specimens, which speeds up the calibration process and increases efficiency.

Dry block function: Precise and uncomplicated calibration

The dry block function of the TP 17200S has been specially developed to enable fast and accurate calibration bothin the laboratory and in the field. The use of the appropriate transition sleeve ensures an optimum thermal connection between the block and the test specimen.

  • Optimum heat transfer: The transition sleeve should have an inner diameter that is approximately 0.5 mm larger than the outer diameter of the test specimen. This ensures efficient thermal coupling and precise calibration.
  • Universal application: The TP 17200S can calibrate almost all straight temperature sensors of different lengths and diameters by using the appropriate adapter sleeves.

No need to change the calibration medium

The dry block covers the entire temperature range from -55 °C to 200 °C without the need to change the calibration medium. The user therefore does not have to worry about viscosities, flash points or outgassing, which makes the calibration process considerably easier and faster.

Technical data:

  • Temperature range: -55...200 °C
  • Accuracy: ±0.2 °C
  • Calibration medium: Dry block

Summary

The SIKA TP 17200S dry block temperature calibrator offers a precise, efficient and user-friendly solution for calibrating temperature sensors. The dry block technology eliminates the use of liquids, making the calibration process easier, faster and safer. With its compact design, high accuracy and ability to calibrate multiple DUTs simultaneously, the TP 17200S is the ideal choice for use in workshops, laboratories and test rooms where reliability, efficiency and precision are required

 