Type TP 17650 TP Basic Dry Block Temperature Calibrator Room temperature...650 °C Accuracy ±0.8 °C or 1°C

Compact design for on-site use / Simple calibration regardless of viscosities, flash points or outgassing / Large calibration volume for simultaneous calibration of many test specimens / Optimum thermal coupling from block to test specimen thanks to SIKA transition sleeves

Operating instructions for SIKA temperature calibrator TP Basic

The SIKA TP Basic dry-block temperature calibrator is a compact, precise calibration device that has been specially developed for on-site use. With a temperature range from room temperature to 650 °C and an accuracy of ±0.8 °C or ±1 °C, the calibrator is suitable for a wide range of applications in various industries:

  • Assembly and commissioning
  • Manufacturing and production
  • Maintenance and service
  • Quality assurance
  • Test equipment monitoring
  • Repair

Features of the TP Basic:

  • Temperature range: room temperature up to 650 °C
  • Accuracy: ±0.8 °C or ±1 °C
  • Compact design: Developed for mobile use on site, the TP Basic facilitates calibration in different environments.
  • Large calibration volume: Provides space for the simultaneous calibration of several test samples and increases the efficiency of the calibration process.

Dry block function: Precise and simple calibration

The dry block function of the TP Basic has been specially developed to enable fast and accurate temperature calibration both in the laboratory and in the field. This technology eliminates the need for liquid calibration media, making the calibration process simpler and safer.

  • Optimum heat transfer: Efficient thermal coupling between the block and the test specimen is ensured by the correct adapter sleeve. The bore of the sleeve should have an inner diameter that is 0.5 mm larger than the outer diameter of the test specimen to ensure exact calibration.
  • Versatile application: Almost all straight temperature sensors of different lengths and diameters can be calibrated with the appropriate adapter sleeves.

Flexibility without changing the calibration medium

The dry block covers the entire temperature range up to 650 °C without the need to change the calibration medium. This means that the user does not have to worry about viscosities, flash points or outgassing, which considerably simplifies and speeds up the calibration process.

Technical data:

  • Accuracy: ±0.8 °C / ±1 °C
  • Power supply:
    • 230...240 VAC, 50/60 Hz
    • 100...115 VAC, 50/60 Hz
    • 100...240 VAC, 50/60 Hz
  • Approvals: Without / DNV-GL

Summary

The SIKA TP Basic dry block temperature calibrator offers an efficient, flexible and precise solution for temperature calibration in many different applications. The dry block technology eliminates the need to change the calibration medium, making the process easier, faster and safer. With its compact design, high accuracy and the ability to calibrate multiple test items simultaneously, the TP Basic is the ideal choice for workshops, laboratories and test rooms where reliability, efficiency and ease of use are required.

 

Accuracy
±0,8 °C
±1 °C

 

Power supply
230...240 VAC, 50 / 60 Hz
100...115 VAC, 50 / 60 Hz
100...240 VAC, 50 / 60 Hz

 

Approvals
Without
DNV-GL

Technical data

 

 

 

 

Request

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Request

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.