GRUBATEC AG Measurement & Control Technology

Type TP 17650S TP Solid Dry Block Temperature Calibrator Room temperature...650 °CAccuracy ±0.4 °C

Compact design for on-site use / Easy calibration without regard to viscosities, flash points or outgassing / Large calibration volume for simultaneous calibration of many test specimens /Optimal thermal coupling from block to test specimen due to SIKA transition sleeves

Operating instructions for SIKA temperature calibrator type TP 17650S - TP Solid

The SIKA TP 17650S dry-block temperature calibrator (TP Solid) is a highly accurate and compact instrument specifically designed for on-site use. With a temperature range from room temperature to 650 °C and an accuracy of ±0.4 °C, this calibrator offers a reliable solution for calibrating temperature sensors in a wide range of applications:

  • Assembly and commissioning
  • Manufacturing and production
  • Maintenance and service
  • Quality assurance
  • Test equipment monitoring
  • Repair

Features of the TP 17650S:

  • Temperature range: room temperature up to 650 °C
  • Accuracy: ±0.4 °C
  • Compact design: Specially developed for mobile use on site, the TP Solid offers high flexibility and easy handling.
  • Large calibration volume: Enables simultaneous calibration of multiple test samples, which increases efficiency and optimizes the calibration process.

Dry block function: Precise and simple calibration

The dry block function of the TP 17650S has been specially developed to enable fast and precise temperature calibration in the laboratory and in the field. This technology does not require the use of liquid calibration media, making the calibration process much simpler and safer.

  • Optimum heat transfer: Correct thermal coupling between the block and the test specimen is ensured by using the correct transition sleeve. The sleeve should havean inner diameterthat is 0.5 mm larger than the outer diameter of the test piece to ensure exact calibration.
  • Versatile application: The TP 17650S can calibrate almost all straight temperature sensors with different lengths and diameters by using the appropriate adapter sleeves.

No need to change the calibration medium

The dry block covers the entire temperature range from room temperature to 650 °C without the need to change the calibration medium. The user does not have to worry about viscosities, flash points or outgassing, which considerably simplifies and speeds up the calibration process.

Power supply:

  • Tension:
    • 230...240 VAC, 50/60 Hz
    • 100...115 VAC, 50/60 Hz
    • 100...240 VAC, 50/60 Hz

Summary

The SIKA TP 17650S dry block temperature calibrator offers a precise, flexible and user-friendly solution for the calibration of temperature sensors in various industries. The dry block technologyeliminates the need for liquid calibration media, making the process safer, faster and easier. With its compact design, high accuracy and ability to calibrate multiple test samples simultaneously, the TP 17650S is the ideal choice for workshops, test rooms and laboratories that require reliability, efficiency and precision.

 

Power supply
230...240 VAC, 50 / 60 Hz
100...115 VAC, 50 / 60 Hz
100...240 VAC, 50 / 60 Hz

 

Technical data

 

 

 

 

Request

Request

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.