GRUBATEC AG Measurement & Control Technology

Type TP 18850E TP Basic Dry Block Temperature Calibrator Room temperature...850 °C Accuracy ±1 °C

Compact design for on-site use / Easy calibration without regard to viscosities, flash points or outgassing / Optimal thermal coupling from block to test specimen due to SIKA transition sleeves

Operating instructions for SIKA Type TP 18850E - Basic dry-block temperature calibrator

The SIKA TP 18850E dry-block temperature calibrator is designed for temperature calibrations in the range from room temperature to 850 °C. It offers a compact design for on-site use, in the workshop, in the measuring room or in the laboratory. With an accuracy of ±1 °C, it enables precise calibrations without taking viscosities, flash points or outgassing into account.

Features:

  • Compact design: Ideal for on-site use as well as for use in the laboratory or measuring room.
  • Simple calibration: Enables quick and uncomplicated calibration of temperature sensors without special requirements for the calibration medium.
  • Optimum thermal coupling: The use of SIKA transition sleeves ensures optimum heat transfer between the block and the test object.

Areas of application:

The TP 18850E dry block calibrator is used in numerous industries including:

  • Installation and commissioning: For calibrating temperature measuring devices during the installation of systems.
  • Manufacturing and production: Regular inspection and calibration of temperature sensors to ensure production quality.
  • Maintenance and service: To ensure the correct functioning of temperature measuring devices during the maintenance of machines and systems.
  • Quality assurance and test equipment monitoring: Regular monitoring of measurement accuracy in production.
  • Repair: Precise calibration of temperature sensors after repairs or replacement.

Mode of operation:

The dry block function of the TP 18850E enables simple and precise temperature calibration both in the laboratory and in the field. An optimal thermal connection between the block and the test object is ensured by using the correct transition sleeve. The sleeve should have an inner diameter that is 0.5 mm larger than the outer diameter of the test object. This allows the calibration of almost all straight temperature sensors with different lengths and diameters. The dry block covers the entire temperature range without the need to change the calibration medium.

Advantages:

  • Calibration regardless of viscosities and flash points: The calibrator can be used regardless of the physical properties of the medium.
  • High-precision measurements: Rapid temperature stabilization enables fast calibration and increases productivity.
  • Wide range of applications: Perfect for on-site applications, workshops and laboratories where reliable temperature measurements are crucial.

Technical data:

  • Temperature range: room temperature up to 850 °C
  • Accuracy: ±1 °C
  • Power supply:
    • 230...240 VAC, 50 / 60 Hz

 

Power supply
230...240 VAC, 50 / 60 Hz