Type VH500 Flow switch for direct mounting Metal version for marine applications DN 25...DN 50 Switching range ON 18,33...14,66 l/min / Switching range OFF 17,5...141,66 l/min
DNV GL type approval / Suitable for water, oil, etc. / Adaptation to nominal size and switching point adjustment by selecting the impact vane / Direct installation in pipelines or T-pieces DN 25...DN 50 / High switching currents due to microswitch as signal generator / Vibration resistance up to 4 g
SIKA flow monitors monitor the liquid flow of low-viscosity media in pipelines. The SIKA paddle flow monitor VH500 is particularly suitable for marine applications such as cooling water monitoring, lubrication control and leakage monitoring of marine engines and compressors.
In this flow monitor, the flowing medium strikes an impact vane attached to the end of a paddle. The resulting dynamic pressure causes the paddle to deflect and actuate a microswitch.
| Operating pressure |
| 6 bar |
| 10 bar |
| Process connection |
| G 1 |
| M33 x 2 |
| Series | VH500 |
| Technical data | DNV GL type approval Suitable for water, oil, etc. Adaptation to nominal size and switching point adjustment by selection of impact lug Direct installation in pipelines or T-pieces DN 25.-DN 50 High switching currents due to microswitch as signal transmitter Vibration resistance up to 4 g |
| Switching function | Changeover contact |
| Operating pressure (test pressure) | Max. 6 bar (10 bar) or max. 10 bar (15 bar) |
| Temperatures | |
| Medium | Max. 100 oc |
| Environment | Max. 85 oc |
| Electrical data | |
| Max. Contact load capacity | 24 VDC, 60 VDC. |
| 250 VAC. 10 A resistive load 10 A inductive load | |
| Protection class EN 60529 | P54 |
| Protection class EN 60730-1 | Class I |
| Approvals | |
| Nominal diameter of the pipe section | Baffle dimensions** | Switching point ranges [m3/h]* | |
| Rising flow ON | Falling flow OFF | ||
| DN 25 | 25 x 30 mm | .O.__ 1,25 | 1 .05__.1 .2 |
| DN 32 | 25 x 38 mm | 1.7._2.05 | |
| DN 40 | 25 x 46 mm | 2.2.__2.55 | 2.1 ._2.45 |
| DN 50 | 25 x 58 mm | 3.25_._3.85 | 3.1 5__.3.75 |
| - Water. 20 oc. horizontal pipeline, tolerance 215 %. | |||
| Higher switching points possible by selecting smaller baffles Switching points for larger nominal sizes on request |
Technical data