Type induQ VMZ.2 Magnetic Inductive flow sensors with threaded connection Plastic version Measuring range 0.1...250l/min DN 03... 25

Cost-optimized plastic design / Compact lightweight construction / Especially for series applications / Best price-performance ratio

The flow sensors of the induQ® VMZ.2 series enable precise flow / volumetric flow measurement or metering of electrically conductive liquids without moving parts. They are the ideal choice when accuracy and reliability are required.

Areas of application include:

- Mechanical and plant engineering

- Cleaning processes

- mobile applications

The intelligent flow sensors of the induQ® series operate according to the induction principle: The measuring tube is located in a magnetic field (B). If an electrically conductive medium with the flow rate to be determined (Q) flows through the measuring tube and thus at right angles to the magnetic field, a voltage (U) is induced in the medium which is proportional to the average flow velocity and is tapped by two electrodes. Different variants are available for a flow-proportional output signal:

- Frequency output signal (pulse rate factory configurable depending on type)

- Analog output 4...20 mA and frequency output

- Analog output 0.5...10 V and frequency output

 

Type VMZ03 VMZ06 VMZ08 VMZ15 VMZ20 VMZ25
Technical data
Nominal width DN3 DN6 DN 8 DN 15 DN 20 DN 25
Process connection [external thread G3/8 G1/2 G 1/2 G3/4 G 1 G 1/4
Inner diameter [mm] 3 6 8 14 18 25
Measuring range [l/minl 0,1...2 0,25.-5 1..20 2,5...50 5...200 12,5...250
Measurement accuracy* ±0.7 % of measured value, ±0.3 % of full scale value
Repeatability ±1 %
Response time <100 ms
Signal output from Il/min) 0.05 0,1 0,25 4 5
Max. Flow rate Il/min) 2,5 6 25 60 240 300
Measuring medium / min. conductivity of the measuring medium Water and other conductive liquids / 20 PS/cm
Media temperature PVDF measuring tube ROM measuring ear -15...80 oc (non freezing) -15...60 sc (non freezing)
Ambient temperature -1 5...60 ec
Storage temperature -1 5...60 ec
Max. Operating pressure 10 bar at 20 'C, 8 bar at 40 'C, 6 bar at 60ec, 5 bar at 80 ec
Flow display LED green, flashes in proportion to the footfall
Protection class EN 60529 IP65 (with plugged-on coupling socket)
Electrical data
Electrical connection 4-pole round plug M12 x 1
Supply voltage 12.24 VDC (±10 %) (With analog output 0.5. 10 v: 16__.24 voc (±10
Power consumption Typically 1.1 W, max. 3.6 W
Protective measures Short circuit proof and reverse polarity protected
test conditions: Ex works water 23 -C

Technical data

Request

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Request