Type TP 18850E TP Basic Dry Block Temperature Calibrator Room temperature...850 °C Accuracy ±1 °C
Compact design for on-site use / Easy calibration without regard to viscosities, flash points or outgassing / Optimal thermal coupling from block to test specimen due to SIKA transition sleeves
Operating instructions for SIKA Type TP 18850E - Basic dry-block temperature calibrator
The SIKA TP 18850E dry-block temperature calibrator is designed for calibrations in the range from room temperature to 850 °C. With its compact design, it is ideal for on-site use as well as for use in the laboratory, measuring room or workshop. Thanks to its accuracy of ±1 °C, the calibrator offers reliable and precise calibration of temperature sensors, regardless of the properties of the medium.
Features:
- Compact design: Perfect for mobile use on site as well as for stationary use in workshops and laboratories.
- Simple calibration: Calibration is quick and precise, without taking viscosities, flash points or outgassing into account.
- Optimum thermal coupling: The use of SIKA transition sleeves guarantees perfect heat transfer between the block and the test object, which ensures exact calibration.
Areas of application:
The TP 18850E dry block calibrator is used in many industries and applications, including:
- Installation and commissioning: Calibration of temperature measuring devices during system setup.
- Manufacturing and production: Regular inspection and calibration of temperature sensors to ensure production quality.
- Maintenance and service: Ensuring the correct functioning of temperature measuring devices through regular calibration.
- Quality assurance and test equipment monitoring: Calibration for compliance with measurement standards in production.
- Repair: Used for checking and adjusting sensors after repairs or replacement.
Mode of operation:
The dry block function of the TP 18850E has been specially developed to enable simple and precise temperature calibration both in the laboratory and in the field. By using the correct adapter sleeve, an optimum thermal connection between the calibration block and the test object is achieved. The sleeve bore should ideally be 0.5 mm larger than the outside diameter of the test object in order to be able to calibrate almost all straight temperature sensors with different lengths and diameters.
The dry block covers the entire temperature range from room temperature to 850 °C without the need to change the calibration medium. This enables efficient and time-saving calibration, as viscosities, flash points or outgassing do not play a role.
Advantages:
- Versatile application possibilities: The TP 18850E is suitable for both stationary and mobile applications as it enables fast and reliable calibration.
- No need to change the calibration medium: The dry block works independently of the physical properties of the medium, which simplifies handling.
- High accuracy: With an accuracy of ±1 °C, the calibrator delivers precise results that ensure measurement accuracy in practice.
- Simple operation: The uncomplicated use of the adapter sleeves means that calibrationcan be carried out quickly foralmost all temperature sensors .
Technical data:
- Temperature range: room temperature up to 850 °C
- Accuracy: ±1 °C
- Power supply:
- 230...240 VAC, 50 / 60 Hz
Summary:
The SIKA TP 18850E dry-block temperature calibrator is a compact and versatile solution for calibrating temperature sensors in the temperature range up to 850 °C. Its ease of use, high accuracy and robust design make it the ideal choice for on-site calibrations, laboratory applications andindustrial temperature monitoring. The TP 18850E enables efficient and precise calibration without taking viscosities, flash points or outgassing into account, which increases flexibility and productivity in various applications.
| Power supply |
| 230...240 VAC, 50 / 60 Hz |
Technical data