AED 1012-PC - Digital evaluation electronics

AED 1012-PC - Digital evaluation electronics

Digital evaluation electronics - Type AED 1012-PC
for digital + analog MAURER - INFRAROT - PYROMETER
PID program controller

  • PID program controller
  • Data logger with real-time clock
  • 500 programs, 1023 program steps
  • Touch panel multilingual
  • Ultra-fast sampling rate of 50μsec
  • automatic scaling for digital pyrometer
  • Parameterization of the pyrometers without PC
  • digital pyrometer interface RS232 or RS485
  • USB 2.0 for PC connection
  • 4 switching outputs with opto relays
  • Power supply for pyrometer

Technical data

Pyrometer interface RS232 switchable RS485
Computer interface USB 2.0
Data logger with USB stick, real-time clock
Input actual value Current loop pyrometer (0-20 mA or 4-20 mA / input impedance 20R)
Measured value display 6-digit programmable, adjustable measuring rate 100ms - 10sec.
Sampling rate 50μsec
Program number 500
Program steps 1023
Program step duration 1ms to 3600ms
PID parameters xp:1-1000%, ti:0.1-9999ms, td: 0.1-9999ms, P: 0-100%
Setpoint specification Program or manual or external 0-10 V / 2-10 V
Control output 0 (4) - 20 mA + 0-10 V
Measuring range Scalable from -50°C to 4000 °C for analog pyrometers
Measuring range automatic scaling for digital pyrometer
Switching outputs Setpoints adjustable within the measuring range
4x opto relays with changeover contacts each 60 VAC / 100mA
Switching hysteresis adjustable between 0-50°C
Response time 2ms
Operating temperature 0 - 60°C
Storage temperature -10 °C - +70°C
Mains connection 80-305 V AC (IEC plug)
Current consumption max. 250mA / AC
Pyrometer supply + 24V / 300 mA (D-SUB)
Signal outputs via screw terminal strip
Weight 1.3 kg
Housing color Frame RAL 7030 (stone gray), cover + U-profiles RAL 7032 (pebble gray)

 

Options:
PROFIBUS, PROFINET, Ethernet Housing stand for mounting
Additional current output 0(4)-20mA Mounting bracket for panel mounting
Connection option for up to 6 pyrometers RS485 2. pyrometer connection via RS232

 