GRUBATEC AG Measurement & Control Technology

KTRD 4485 - Infrared pyrometer 600-2500°C steel, wires, casting, hardening, rolling, induction heating, forging, melting

Infrared pyrometer KTRD 4085 - steel, wires, casting, hardening, rolling, induction heating, forging, melting

Series KTRD 4485-1
Temperature ranges 600 to 2500°C

Temperature control during production processes
Compact devices - 60 years of experience and digital technology make it possible!

  • Light guide with optics
  • Light beam aiming device with LED
  • Emissivity adjustable on the device
  • Analog and digital output
  • 1 switching output (open collector)
  • Software IR-LOG

Additional functions can be parameterized via the serial interface:

  • Analog output: 0 - 20 / 4 - 20 mA switching
  • Zoom range within the measuring range
  • Emissivity: 100.00 - 10.00 %
  • Averaging: arithmetic or sliding
  • Maximum value memory: Memory types and delete functions, e.g. automatically with new part

Fields of application:
Steel, iron, non-ferrous metal, wires, ceramics, glass feeder, glass tank, glass vault, hardening, rolling, induction heating, brazing, forging, welding, forming, vacuum furnace, etc.

Technical data

Device types KTRD 4485-1
Measuring spot marking Light beam aiming device LED green
Measuring ranges short: MB 1: 600 - 1200°C D=85
MB 2: 650 - 1300°C D=85
MB 3: 700 - 1400°C D=85
MB 4: 750 - 1500°C D=85
MB 5: 800 - 1700°C D=85
MB 6: 900 - 2000°C D=85
Measuring ranges long: MB 7: 600 - 1600°C D=85
MB 8: 700 - 2000°C D=85
MB 9: 850 - 2500°C D=85
Special measuring ranges on request
Spectral range 0.85 - 1.1 μm
Response time 1 ms
Accuracy 0,5 % ± 1°C
Reproducibility 1 ‰
Emission factor 100 - 10 %
Operating temperature 0 - 60°C
Storage temperature -10°C - +70°C
Temperature dependence 0,01 % / °C
Permissible humidity 35 - 85 % RF
Analog output 0 - 20 mA or 4 - 20 mA
1 switching output (open coll.) 24 V 100 mA
Interface RS 232 ± 50 V isolated
Current consumption < 100 mA
Device connection 8-pin plug connection
Dimensions H / W / D 65 x 30 x 80 mm
Weight 0.15 kg
Protection class IP 65

 

Objective:
A focusable lens is available for optimum adaptation to the respective measuring task: Adjustment range 100 mm to infinity, distance ratio: D = 85
The measuring field size is calculated: Measuring distance M mm
Distance ratio D

 

Mechanical accessories Electrical accessories Evaluation electronics
Version in cooling housing Connection cable 8-pin AED 1012
Blowing attachments Power supply unit 230 VAC 24 VDC AED 1012-C PID controller
Beam deflection 90° Digital display in built-in version AED 1012-PC Program controller
Assembly parts

Request

Request

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
GRUBATEC Mess- und Regeltechnik